Forged steel fixed ball valve (electric)

Technical Specifications

Valve model: Q947F/H 
Piping specification: DN25 to 700mm 
Structural form: Two-section cast valve body 
Valve body material: Cast steel (WCB), Stainless steel (304, 316, 316L) 
Nominal pressure: PN1.6, 2.5, 4.0, 6.4 MPa 
Applicable temperature range: -40℃ to 425℃ 
Application scope: Petrochemical industry, gas equipment, power equipment, environmental water treatment

Sales Hotline:

0086-21-59110018

Product Details

Product structural characteristics

The series of fixed ball valves are mainly applicable to industries such as natural gas, oil products, chemical engineering, metallurgy, urban construction, environmental protection, pharmaceuticals, food, etc. Among them, the anti-sulfur series is suitable for natural gas long-distance pipelines with hydrogen sulfide-containing media, high impurity content, and severe corrosion.


Its main structural features are:

Shell structure: The valve body of the fixed ball valve can be designed in three forms according to the user's requirements and actual working conditions: casting structure, forging structure, and fully welded structure. Among them, the fully welded structure ball valve is mainly suitable for underground use. 
2. Valve seat sealing structure: For fixed ball valves, the sealing structure is selected based on the pressure level, the nature of the medium, and the sealing requirements. It can be the front seal structure, the rear seal structure, or the dual seal structure at both the front and rear. 
3. Automatic Pressure Relief Structure: When the pressure in the middle chamber abnormally rises, the ball valve with a single-sealed structure has the function of automatic pressure relief, while the ball valve with a double-sealed structure is relieved by the additional pressure relief device on the valve body. 
4. Sealed emergency rescue: When the sealing components of the valve seat and valve stem are damaged and cause leakage, the sealing grease injected through the grease injection valve can provide a temporary sealing effect. 
5. Fireproof Structure; According to the working conditions and the needs of the users, the ball valve can be designed as a fireproof structure. The fire-resistant design of the ball valve complies with the provisions of standards such as API 607, API 6FA and JB/T 6899. In the event of a fire causing the soft sealing ring to burn out, the fireproof structure of the ball valve can prevent a large amount of medium from leaking and prevent the further expansion of the fire. 
6. Anti-static structure: When operating the valve, due to the friction between the ball and the valve seat, static electric charges will be generated and accumulate on the ball. To prevent the occurrence of static sparks, an anti-static device is specially installed on the valve to discharge the accumulated charges on the ball. 
7. Blocking and Discharge: When the valve is in the closed position, the valve seats at both the upstream and downstream sides block the flow of fluid. The accumulated substances in the chamber of the valve body can be discharged through the discharge device. 
8. Locking Device: A locking structure is designed at the fully open and fully closed positions of the manual ball valve. This ensures that accidental operation is prevented and abnormal switching phenomena caused by unpredictable line vibrations are avoided. Especially in the production lines of flammable media such as petroleum and chemical substances, as well as when the valve is installed outdoors, this design demonstrates particularly excellent advantages and practical effects. 
9. Full-bore structure and reduced-bore structure: To meet the diverse needs of users, our ball valve products are available in both full-bore and reduced-bore series. The inner diameter of the channel in the full-bore ball valve is consistent with the inner diameter of the pipeline, which is convenient for management and cleaning. While the reduced-bore series ball valves are relatively lightweight in weight, and the fluid resistance is only about 1/7 of that of the same-sized stop valve. Therefore, the application prospects of the reduced-bore series ball valves are more extensive.


Main connection dimensions(PN1.6MPa)

DN

25

32

40

50

65

80

100

125

150

200

250

300

350

400

450

500

600

700

d1

25

32

40

50

65

80

100

125

150

200

250

300

337

387

438

489

591

686

L

165

180

190

216

241

283

305

356

394

457

533

610

686

762

864

914

1067

1245

H

50

55

80

102

114

127

152

184

219

273

360

395

430

470

550

580

700

800

Electric

H2

-

-

-

-

-

-

-

-

554

600

652

760

770

830

-

940

940

1115

L1

-

-

-

-

-

-

-

-

235

235

235

259

400

400

-

410

410

410

 

Main connection dimensions(PN2.5MPa)

DN

25

32

40

50

65

80

100

125

150

200

250

300

350

400

450

500

600

700

d1

25

32

40

50

65

80

100

125

150

200

250

300

337

387

438

489

591

686

L

165

180

190

216

241

283

305

381

403

502

568

648

762

838

914

991

1143

1346

H

50

55

80

102

114

127

152

184

219

273

360

395

430

470

550

580

700

800

Electric

H2

-

-

-

-

-

-

-

-

235

235

400

400

410

410

-

420

690

690

L1

-

-

-

-

-

-

-

-

74

350

350

420

420

400

-

400

410

650

 

Main connection dimensions(PN4.0MPa)

DN

25

32

40

50

65

80

100

125

150

200

250

300

350

400

450

500

600

700

d1

25

32

40

50

65

80

100

125

150

200

250

300

337

387

438

489

591

686

L

165

180

190

216

241

283

305

381

403

502

568

648

762

838

914

991

1143

1346

H

50

55

80

102

114

127

152

184

219

273

360

395

430

470

550

580

700

800

Electric

H2

-

-

-

-

-

-

-

-

235

235

400

400

410

410

-

420

690

690

L1

-

-

-

-

-

-

-

-

74

350

350

420

420

400

-

400

410

650

 

Main connection dimensions(PN6.4MPa)

DN

50

65

80

100

150

200

250

300

350

400

500

600

700

d1

50

65

80

100

150

200

250

300

337

387

489

591

686

L

292

330

356

406

495

597

673

762

826

902

1054

1232

1397

H

114

124

133

159

250

294

395

445

500

530

660

800

900

Electric

H2

-

-

-

-

554

574

731

771

867

802

979

1085

1148

L1

-

-

-

-

235

235

400

400

410

410

420

690

690